This article will provide guidelines and precautions for removing and installing the Heatbed Sensor Unit (functions as an accelerometer) at the bottom of the Heatbed.
The spare parts involved in this guide are as follows.
No. | Descriptions | Pictures |
1 | Heatbed Sensor Unit |
None
Model | Locations | Dimensions/Drawing | Model | Locations | Dimensions/Drawing | ||
Screw A |
M3-6 |
Heatbed Unit (4PCS) |
Screw B |
ST3-4.5 |
Sensor Unit (1PCS) |
Disconnect the Power Cord.
IMPORTANT!
It's crucial to power off the printer before performing any maintenance work on the printer and its electronics, including tool head wires, because leaving the printer on while conducting such tasks can cause a short circuit, which can lead to additional electronic damage and safety hazards.
When you perform maintenane or troubleshooting on the printer, you may be required to disassemble some parts, including the hotend. This process can expose wires and electrical components that could potentially short circuit if they come into contact with each other or with other metal or electronic components while the printer is still on. This can damage the electronics of the printer and cause further damage.
Therefore, it's essential to switch off the printer and disconnect it from the power source before doing any maintenance work. This will prevent any short circuits or damage to the printer's electronics. By doing so, you can avoid potential damage to the printer's electronic components and ensure that the maintenance work is performed safely and effectively.
If you have any concerns or questions about following this guide, open a new ticket in our Support Page and we will do our best to respond promptly and provide you with the assistance you need.
Turn the bottom base over so that the heatbed is facing up, and remove the 4 soft rubber plugs.
Using an H2.0 hex key, unscrew the 4 screws and then remove the Heatbed Unit.
Using tweezers, carefully remove part of the silicone and pry up the connector.
Disconnect the cable, then remove 1 screw with a cross screwdriver to detach the Heatbed Sensor Unit.
Install the Heatbed Sensor Unit to the bracket under the Heatbed Unit and secure it with 1 screw.
Connect the sensor cable and insert the connector into the buckle.
Apply white glue to reinforce the connector and let it sit for 30 minutes.
Confirm the installation position and place the Heatbed Unit on the bracket. Viewing from the left or right will make it easier for you to align the screw holes, and then tighten the 4 screws to secure it in place. Finally, place back the 4 soft rubber plugs.
None
Perform equipment calibration, primarily focusing on Auto Bed Leveling.
We hope that the detailed guide we shared with you was helpful and informative.
We want to ensure that you can perform it safely and effectively. If you have any concerns or questions regarding the process described in this article, we encourage you to reach out to our friendly customer service team before starting the operation. Our team is always ready to help you and answer any questions you may have.