AMS 2 Pro (Hereinafter referred to as AMS)
The intake/vent assembly is the air inlet and outlet of the AMS drying function, forming hot and cold air circulation.
The vents of the intake (side wall) and vent (bottom) assemblies are exactly the same. The only difference is their cable length. The spare parts you receive include one vent, two cables and four screws.
The air intake and vent functions are abnormal, and an HMS error message appears, prompting that the module needs to be replaced; or the after-sales technical support team determines that the module needs to be replaced after determining the fault.
New AMS 2 Pro Air Intake/Vent Assembly
H2.0 Allen key
H1.5 Allen key
20 minutes
IMPORTANT!
It's crucial to power off the printer before conducting any maintenance work, including work on the printer's electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.
During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer's electronics and additional issues.
Therefore, it's crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer's electronics, ensuring safe and effective maintenance. For any concerns or questions about following this guide, we recommend submitting a technical ticket regarding your issue and we will do our best to respond promptly and provide the assistance you need.
Before starting, make sure the AMS is disconnected from the printer.
Press the PTFE tube release button from the back of the AMS to unlock the fitting, then pull the PTFE tube out from the back of the AMS.
Pinch the clip from the inside of the lower cover to automatically pop open the PTFE tube release button, and then pull out the PTFE tube release button from the back of the AMS.
When squeezing the buckle, use your other hand to hold the PTFE tube from the back of the AMS to release the switch to prevent the spring from being ejected and lost.
Remove the driven support sleeve assembly of the two middle slots to expose the two screw holes. When removing the bearing sleeve, be careful with the bearings at both ends to avoid losing them.
Remove the two screws A that secure the AMS main frame.
Lift the rear part of the main frame completely and place it vertically on the lower cover of the AMS. Note that there are cables connected, so do not operate violently. When lifting, it is recommended to lift the front part of the main frame first, and then push it forward to make room for the rear part of the frame.
When placing the AMS main frame vertically, avoid the electronic components of the vent to prevent them from being crushed.
Unlock the plug buckle, unplug the signal cable and power cable on the AMS power board, and lift out the AMS main frame assembly as a whole.
The air intake is on the side wall, and the air vent is on the bottom. According to the actual situation, remove the 2 screws B or screw C of the corresponding vent, unplug the plug on the vent, and pull out the vent.
Considering that cables generally do not fail, when replacing the vent assembly, you can replace the vent first without replacing the cable. If the fault still exists after replacing the vent, then replace the cable.
After aligning the screw holes, push in the direction of the screw holes to press the vent to the corresponding hole, tighten the 2 screws B or C of the vent, and plug the vent back in.
When installing, pay attention to the direction of the vent. If the installation direction is wrong, the vent cannot be stuck in place. Do not press it down violently. The opening direction of the socket of the air intake faces upward, and the opening direction of the socket of the air vent faces right.
Install the AMS main frame assembly into the AMS lower cover and connect the signal cable and power cable to the AMS power board.
After the AMS main frame is installed in place, tighten the two screws to secure it.
Install the two middle driven support sleeve assemblies, making sure that the bearings on both ends of all support shafts are pressed into place.
Press the PTFE tube release button back into the housing in the following direction, insert the buckle into the corresponding slot smoothly, and keep the black silicone housing embedded flat.
Check to make sure that the PTFE tube silicone bracket is aligned with the filament hole of the filament hub unit, and push the PTFE tube from the rear of the AMS. After installation, pull the PTFE tube to confirm that the PTFE tube is fixed.
Connect the power cable, connect the AMS to the printer, turn on the power, and start using the AMS to load filaments through the operation on the screen. If the loading can be completed and no error prompts appear during the entire loading process, the replacement is successful.
Otherwise, please check all connections and try again. If the problem persists, please contact Bambu Lab service team for further assistance.
We hope the detailed guide provided has been helpful and informative.
If this guide does not solve your problem, please submit a technical ticket, we will answer your questions and provide assistance.
If you have any suggestions or feedback on this Wiki, please leave a message in the comment area. Thank you for your support and attention!