The automatic top vent is installed on the upper frame of the printer and controls the closing of the vent through a motor.
The spare parts of the automatic top vent include the following:
Automatic top vent*1
Swing rod*1
Automatic top vent is broken
Swing rod is broken
New automatic top vent
H1.5 Allen key
The screw specifications and quantities involved in replacing the H2D automatic top vent kit (it is recommended to properly store the removed screws to prevent loss).
Screw specifications | Screw image | Location | Location diagram | Screw quantity | |
---|---|---|---|---|---|
BT2×12 | Used to fix the front cover | ![]() |
1 |
IMPORTANT!
It's crucial to power off the printer before conducting any maintenance work, including work on the printer's electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.
During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer's electronics and additional issues.
Therefore, it's crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer's electronics, ensuring safe and effective maintenance. For any concerns or questions about following this guide, we recommend submitting a technical ticket regarding your issue and we will do our best to respond promptly and provide the assistance you need.
Just remove the screen and front cover together. No need to remove the screen from the front cover.
Please pull it out carefully to avoid damaging the screen cable!
The automatic top vent is buckled on the upper frame by 4 buckles and connected to the motor through a swing rod.
If the swing rod is damaged during replacement, a spare swing rod can be used.
Check that all the clips and swing rods of the automatic top vent are in place and can control the opening and closing of the vent normally.