When printing with low-temperature filaments, excessive chamber temperatures can lead to hotend clogging and degrade print quality. Timely chamber cooling is required to maintain optimal printing conditions.
Users may adjust the order of these solutions as needed.
Check whether the active chamber exhaust and automatic top vent are open normally.
Active chamber exhaust:
Automatic top vent:
Check whether the chamber exhaust fan is turned on normally.
Click on the screen: Control > Air Condition > Exhaust, check if the fan is on.
Chamber exhaust fan (back view, after removing the active chamber exhaust):
Check if the external environment temperature of the printer is too high, and move it to normal temperature.
Check if the chamber temperature sensor is damaged.