Function: The completion of an AMS filament retraction is marked by the filament retracting back into the PTFE tube between the feeder unit and the internal hub unit. If the retraction time exceeds the maximum limit without success, and the AMS detects no other errors, it will prompt "AMS x slot x filament retraction to AMS timed out".
Common causes for this failure include:
The end of the filament has detached from the spool but has not fully entered the feeder (the Hall effect sensor is still triggered). In this state, although the spool can rotate, it cannot pull and retract the filament.
The length of the filament to be retracted is too long, causing the retraction process to time out.
The following HMS codes all represent the same type of fault.
HMS Code | Fault Description |
---|---|
0700-2000-0002-0011 | AMS A slot 1 filament retraction to AMS timed out. |
0700-2100-0002-0011 | AMS A slot 2 filament retraction to AMS timed out. |
0700-2200-0002-0011 | AMS A slot 3 filament retraction to AMS timed out. |
0700-2300-0002-0011 | AMS A slot 4 filament retraction to AMS timed out. |
0701-2000-0002-0011 | AMS B slot 1 filament retraction to AMS timed out. |
0701-2100-0002-0011 | AMS B slot 2 filament retraction to AMS timed out. |
0701-2200-0002-0011 | AMS B slot 3 filament retraction to AMS timed out. |
0701-2300-0002-0011 | AMS B slot 4 filament retraction to AMS timed out. |
0702-2000-0002-0011 | AMS C slot 1 filament retraction to AMS timed out. |
0702-2100-0002-0011 | AMS C slot 2 filament retraction to AMS timed out. |
0702-2200-0002-0011 | AMS C slot 3 filament retraction to AMS timed out. |
0702-2300-0002-0011 | AMS C slot 4 filament retraction to AMS timed out. |
0703-2000-0002-0011 | AMS D slot 1 filament retraction to AMS timed out. |
0703-2100-0002-0011 | AMS D slot 2 filament retraction to AMS timed out. |
0703-2200-0002-0011 | AMS D slot 3 filament retraction to AMS timed out. |
0703-2300-0002-0011 | AMS D slot 4 filament retraction to AMS timed out. |
1800-2000-0002-0011 | AMS-HT A filament retraction to AMS timed out. |
1801-2000-0002-0011 | AMS-HT B filament retraction to AMS timed out. |
1802-2000-0002-0011 | AMS-HT C filament retraction to AMS timed out. |
1803-2000-0002-0011 | AMS-HT D filament retraction to AMS timed out. |
1804-2000-0002-0011 | AMS-HT E filament retraction to AMS timed out. |
1805-2000-0002-0011 | AMS-HT F filament retraction to AMS timed out. |
1806-2000-0002-0011 | AMS-HT G filament retraction to AMS timed out. |
1807-2000-0002-0011 | AMS-HT H filament retraction to AMS timed out. |
We hope the detailed guide provided has been helpful and informative.