The assist motor feeds or retracts filament during material changes and helps during printing. When the device detects excessive resistance in the assist motor, this alarm will pop up and automatically retry.
This error indicates: The assist motor encounters excessive resistance during feeding, preventing it from continuing to push the filament. The point of high resistance is located in the PTFE tube between the Filament Buffer and Toolhead.
PTFE tube on the toolhead (using H2D as an example):
PTFE Tube High Resistance
Filament Spool Rotation Resistance
Filament Tangling
Other Causes
The following HMS codes all represent the same type of fault.
Code | Description |
---|---|
0700-2000-0002-0021 | AMS A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0700-2100-0002-0021 | AMS A Slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0700-2200-0002-0021 | AMS A Slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0700-2300-0002-0021 | AMS A Slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0701-2000-0002-0021 | AMS B Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0701-2100-0002-0021 | AMS B Slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0701-2200-0002-0021 | AMS B Slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0701-2300-0002-0021 | AMS B Slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0702-2000-0002-0021 | AMS C Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0702-2100-0002-0021 | AMS C Slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0702-2200-0002-0021 | AMS C Slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0702-2300-0002-0021 | AMS C Slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0703-2000-0002-0021 | AMS D Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0703-2100-0002-0021 | AMS D Slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0703-2200-0002-0021 | AMS D Slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
0703-2300-0002-0021 | AMS D Slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1800-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1801-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1802-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1803-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1804-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1805-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1806-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
1807-2000-0002-0021 | AMS-HT A Slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead. |
We hope this guide provides helpful information and assists you in resolving the issue.
If the issue persists, please contact online technical support (service hours: 9:00–21:00). We are always ready to assist you.
If you have any suggestions or feedback regarding this Wiki, feel free to leave a comment. Thank you for your support and attention!