HMS_0300-9000-0001-0010: The communication of chamber temperature controller is abnormal.
The chamber temperature control board is connected and communicates with the MC board through cables. This fault indicates that the communication between the chamber temperature control board and the MC board has encountered an abnormality.
When powering on, observe whether the green power light on the chamber temperature control board is on. If it does not light up, the chamber temperature control board is damaged. After powering off, reconnect the communication cable and power on again to see if the problem is solved. The position of the power LED light and the communication cable is shown in the following figure:
If the problem can not be solved after taking the above measures, please contact the after-sales team.
We hope the detailed guide provided has been helpful and informative.
To ensure a safe and effective execution, if you have any concerns or questions about the process described in this article, we recommend submitting a Technical ticket regarding your issue. Please include a picture or video illustrating the problem, as well as any additional information related to your inquiry.