The temperature control of chamber heater 1/2 is abnormal.
HMS_0300-9100-0001-0001: The temperature of chamber heater 1 is abnormal. The heater may have a short circuit.
HMS_0300-9200-0001-0001: The temperature of chamber heater 2 is abnormal. The heater may have a short circuit.
There are two heaters in the chamber temperature control module. A short circuit will cause the chamber temperature control module to fail to work properly. This error code indicates a short circuit problem in the heaters.
Please turn off the power and check whether there is a short circuit between the heater connectors. After the problem is eliminated, you can power it on again and see if the problem still exists. Note that powering on again in this situation may cause a short circuit. It is recommended to operate with caution while ensuring safety.
If the problem can not be solved after taking the above measures, please contact the support team.
We hope the detailed guide provided has been helpful and informative.
To ensure a safe and effective execution, if you have any concerns or questions about the process described in this article, we recommend submitting a Technical ticket regarding your issue. Please include a picture or video illustrating the problem, as well as any additional information related to your inquiry.