HMS_0C00_0100_0001_0003: Micro Lidar Synchronization abnormal
This error message occurs when the synchronization between different Micro Lidar subsystems (mainly the mc and camera sensor) is lost.
It should not happen on normal printers. When this message shows up, there is an abnormal synchronization signal between the Micro Lidar subsystems,
which will cause the related functions of the lidar system to work abnormally.
None
Please try to start the printing task several times to observe whether the message prompt occurs frequently. If the message disappears and only occurs
occasionally after restarting printing, it means that the software time synchronization fails. In this case, it is a software error and can be ignored.
If restarting multiple printing tasks, the message still prompts, indicating that it is a hardware problem. Usually, the hardware synchronization signal is abnormal
due to the failure of the circuit board. You need to contact the after-sales service for troubleshooting and hardware replacement.
The message should disappear if problem solved.