This guide provides instructions and precautions for replacing the AMS Lite filament funnel unit. The purpose is to disassemble the filament funnel unit to check whether the gear rotates smoothly.
Since the upper and lower filament funnel unit on both sides are similar in structure, this article only replaces the AMS lite filament funnel unit (3) and explains some precautions.
If needed, please refer to the AMS Lite installation tutorial to learn how to remove and install the AMS Lite Feeder Unit from the AMS Lite.
IMPORTANT!
It's crucial to disconnet the AMS Lite from the printer before performing any maintenance work on the AMS Lite and its electronics, because leaving the AMS Lite connected while conducting such tasks can cause a short circuit, which can lead to additional electronic damage and safety hazards.
If you have any concerns or questions about following this guide, open a new ticket in our Support Page and we will do our best to respond promptly and provide you with the assistance you need.
Use an Allen key to carefully pry the top cover from its notched position and remove it.
Unscrew the 3 screws with an H1.5 Allen key to loosen the Filament Funnel Unit, and disconnect the wire connections.
The following steps are used to inspect gear bearings:
NOTE: This can be done on a spool.
2. Use an Allen key to hold one side of the gear and push the pin out with force.
Remove the 2 screws of the filament detection sensor and check if the gear slide normally. If not, please contact the after-sales service team.
Use an H1.5 Allen key to install the 2 screws of the filament detection sensor.
Align the funnel with the buckle and install the pin from the opposite side; hold the knurled side with your hand, insert the non-knurled side first, and then press the pin in firmly.
Align the gear with the buckle and place it. Check whether it is in place by looking at the gaps between the buckles on both sides. Hold the knurled side of the pin with your hand and install the pin from the buckle, making sure the non-knurled side is inserted first.
1. Connect the cable; adjust the position of the swing gear set as shown in the figure, with the outer gear pushed to the left and the inner gear standing up.
2. Install the filament funnel unit and use an Allen key to insert the other end of the spring into the indicated hole, ensuring that the spring is properly installed.
Note that the outer swing gear is under the limit block.
A similar operation can be used to install the AMS Filament Funnel Unit-Left. However, you need to pay attention to the installation position of the gear sets. This installation position is somewhat different from the AMS Filament Funnel Unit-Right. Please see the picture below for details.
Please refer to AMS lite Feeder Unit Installation Tutorial | Bambu Lab Wiki.
3. Fasten it, screw in 3 screws, and connect the cable.
The final installation effect is shown below:
Check whether the light guide column is in position; Confirm the installation direction and install the AMS Feeder Cap.
Push the AMS Filament Funnel Rod by hand to confirm movement and smoothness.
We hope that the detailed guide we shared with you was helpful and informative.
We want to ensure that you can perform it safely and effectively. If you have any concerns or questions regarding the process described in this article, we encourage you to reach out to our friendly customer service team before starting the operation. Our team is always ready to help you and answer any questions you may have.
Click here to open a new ticket in our Support Page.