The hotend fan has a speed feedback signal and is used to keep the filament outside the nozzle cooled and rigid. If the hotend fan speed remains too low, the hotend temperature will rise, causing the filament to become too soft and jam inside the hotend.
The hotend cooling fan is used to keep the filament cool and firm at the nozzle cooling fins. If the hotend cooling fan speed is kept low, the nozzle temperature rises and causes the filament to be too soft and easy to clog in the hotend.
The following are possible reasons for this HMS error:
Warning: The hotend cooling fan may spin unexpectedly during cleaning, posing a risk of injury. Since the fan cannot be turned off, please use a pen or Allen key to safely complete the following step
Set the hotend temperature to 0 °C. The hotend fan will automatically turn off when the temperature drops below 50 °C (and will automatically turn on when the hotend reaches 50 °C).
Remove the front cover, then gently rotate the fan blades using a pencil or screwdriver to check if they are stuck. If you find any obstruction, remove it promptly.
After cleaning the fan, follow Steps 1–2 in the guide:《Replace H2S Part Cooling Fan》:
Once done, set the hotend temperature to 51 °C. The fan should restart (if it is not stuck or damaged). Observe whether the HMS error message disappears.
If the error persists, try replacing the hotend fan with a new one to see if it resolves the issue.
If the above steps do not fix the problem, the TH board may be faulty. Please contact support for replacement.
If the above steps do not resolve your issue, please submit a ticket and upload your printer logs
We hope this guide will provide you with useful information and help you solve problems.
To ensure that you operate safely and effectively, if you have any doubts or questions about any steps in the guide, please contact our Customer Support team before starting the operation.
We are always happy to answer your questions and provide support.
Click here to contact online technical support (service hours 9:00-21:00)
The following HMS codes represent the same type of issue.
HMS代码 | 故障描述 |
---|---|
0300_0300_0001_0001 | The hotend cooling fan speed is too slow or stopped. It may be stuck or the connector may not be plugged in properly. |