As shown in the figure below, a Hall sensor is installed near the top and bottom of the printer's right side window. These sensors work together with magnets on the right window to detect whether the side window is correctly installed. The Hall sensors are connected to the MC board via wiring. If the Hall sensor signal is lost, an alarm will be triggered.
The possible causes of this fault include:
Users may adjust the order of these solutions as needed.
Refer to the Wiki to remove the printer's back panel and reseat the connectors on the MC board.
Right Window Hall Sensor (Upper): Connector 15
Right Window Hall Sensor (Lower): Connector 19
After reconnecting, power on the printer. If the alarm persists, proceed to the next steps.
Refer to the Wiki to remove the printer's right side panel.
Note: Removing and installing the side panel requires some force. Please operate carefully to prevent the Hall sensor wiring from being broken.
Hall Sensor (Upper) | Hall Sensor (Lower) |
---|---|
![]() |
![]() |
If the alarm disappears, troubleshooting is successful.
If the alarm persists, the wiring may be broken or the sensor may be faulty. Please contact customer support for further assistance.
Refer to the Wiki to reinstall the right side panel.
Refer to the Wiki to reinstall the back panel.
The following HMS codes represent the same type of issue.
HMS Code | Description |
---|---|
0300-9900-0001-0002 | The right side window Hall sensor (Lower) is abnormal; please check whether the connection wire is loose. |
0300-9900-0001-0003 | The right side window Hall sensor (Upper) is abnormal; please check whether the connection wire is loose. |
We hope this guide provides helpful information and assists you in resolving the issue.
If the issue persists, please contact online technical support (service hours: 9:00–21:00). We are always ready to assist you.
If you have any suggestions or feedback regarding this Wiki, feel free to leave a comment. Thank you for your support and attention!