The adaptive airflow system consists of the active chamber exhaust, filter switch flap, automatic top vent, and air duct. When the vents that make up the air duct system do not move in place or maintain normally, the adaptive air duct system cannot successfully switch to the corresponding air duct mode. This fault code means that the adaptive air duct system cannot successfully enter the laser/cutting mode, and the fault needs to be eliminated in combination with the specific vents with abnormal movement.
Tweezers (flat tip)
Silicone
In laser mode, the automatic top vent, active chamber exhaust, and filter switch vent are all open.
Therefore, when you encounter this error, please check whether all three vents are open, identify the abnormal vent, and then troubleshoot.
Users may adjust the order of these solutions as needed.
When you encounter this error, please check whether all three vents are open, identify the abnormal vent, and then troubleshoot.
Active chamber exhaust failure → Refer to Wiki: HMS_0300-C000-0001-0001: Active Chamber Exhaust malfunction: it may be stuck.
Filter switch flap failure → Refer to Wiki: HMS_0300-C000-0001-0002: Filter Switch Flap malfunction: it may be stuck.
Automatic top vent failure → Refer to Wiki: HMS_0300-C000-0001-0003: Automatic Top Vent malfunction: it may be stuck.
The following HMS codes represent the same type of issue.
HMS Code | Description |
---|---|
0300-C100-0001-0003 | Adaptive Airflow System can't activate laser/cutting mode; please check the air door status. |
We hope the detailed guide provided has been helpful and informative.
If this guide does not solve your problem, please submit a technical ticket, will answer your questions and provide assistance.
If you have any suggestions or feedback on this Wiki, please leave a message in the comment area. Thank you for your support and attention!